The HemoCue® WBC DIFF System brings the unique benefit of total white blood cell (WBC) count with a 5-part differential within minutes, enabling faster care while saving valuable time and money with a more streamlined workflow.
*Not available in the US, for corresponding US product see hemocue.us
Fitting seamlessly into a variety of clinical applications and even remote field clinics, the benefits are clear. Immediate WBC DIFF counts can mean the difference between waiting and acting at the point of care — helping you move from assessment to treatment in just 5 minutes rather than hours or days.
01
Results in just 5 minutes
02
10 uL of capillary or venous samples
03
Easy to use by non-laboratory personnel
04
Automatic warning for unidentified cells
05
Unique software for internal QC
06
Factory calibrated with no further calibration needed
Customer stories
Sorry, no results were found.
System specifications
Principle
Imaging system characterizing white blood cells that are stained, identified and counted
Parameters
Total Leukocytes (White Blood Cells) and differential (in absolute numbers and %) for:
For individually packaged microcuvettes: once the wrapping of a single packaged microcuvette is opened, it should be used within 10 minutes.
For microcuvette packaged in vial: once the seal of the vial is broken, the microcuvette should be used within 3 months.
Operating temperature
Venous/capillary samples in EDTA: 18-30°C (64-77°F)
Capillary sample from fingerstick: 18-25°C (64-77°F), <90% non-condensing humidity
Dimensions
188 x 157 x 155 mm
(7.40 x 6.18 x 6.10 inches)
Weight
1300 g (2.87 pounds) with batteries installed
Lab-quality results in
three simple steps
1
01
Fill the microcuvette
2
02
Place the microcuvette into the analyzer
3
03
View results within 5 minutes
Frequently Asked
Questions
There are two different controls available: HemoCue® WBC Control and HC WBC Diff Control, which should be used with the HemoCue® WBC System and HemoCue® WBC DIFF System, respectively. These controls are manufactured by R&D Systems, Inc and distributed outside the US by EuroCell Diagnostics.
No, only the HC WBC Diff Control should be used with HemoCue® WBC DIFF System.
The HemoCue® WBC DIFF System can be used with either HemoCue® WBC Microcuvettes (for a total white blood cell count) and HemoCue® WBC DIFF Microcuvettes (for a total white blood cell count with a 5-part differential).
Yes, the HemoCue® WBC DIFF System can be operated with either a power adapter or 6 type C 1.5 V Alkaline batteries. When battery operated, actual performance will vary based on settings, environmental conditions, type of batteries and other factors. Estimated number of measurements using batteries is 20 measurements.
A white blood cell count result should always be interpreted in the context of patient history and other clinical signs. The HemoCue® WBC DIFF system will display a flag or an error code if a problem is detected within the system or samples. The explanations and recommended actions for each flag or error code are described in the manual.
You can find instructional videos for all systems at our Knowledge Center.
Can’t find the answer you’re looking for? Fill in the form and we’ll reach out.