HemoCue® WBC DIFF System

HemoCue®
WBC DIFF System

The HemoCue® WBC DIFF System brings the unique benefit of total white blood cell (WBC) count with a 5-part differential within minutes, enabling faster care while saving valuable time and money with a more streamlined workflow.

*Not available in the US, for corresponding US product see hemocue.us

HemoCue® WBC DIFF System

Product sheet

Télécharger

Key benefits

Fitting seamlessly into a variety of clinical applications and even remote field clinics, the benefits are clear. Immediate WBC DIFF counts can mean the difference between waiting and acting at the point of care — helping you move from assessment to treatment in just 5 minutes rather than hours or days.

01

Results in just 5 minutes

02

10 uL of capillary or venous samples

 

03

Easy to use by non-laboratory personnel

04

Automatic warning for unidentified cells

05

Unique software for internal QC

06

Factory calibrated with no further calibration needed


Customer stories

Sorry, no results were found.

System specifications

Imaging system characterizing white blood cells that are stained, identified and counted

 

Total Leukocytes (White Blood Cells) and differential (in absolute numbers and %) for:

Neutrophils
Lymphocytes
Monocytes
Eosinophils
Basophils

 

Factory calibrated and needs no further calibration

Power adaptor or batteries
(6 type C Alkaline batteries, 1.5 V)

10 µL

Capillary or venous (EDTA) whole blood

Within 5 minutes

0.3-30.0 x 10g/L
(300-30000/mm3, 300-30000/µL)

 

Built-in self-test, image recognition software, warning for unidentified cells

Printer, keyboard, barcode reader, PC

Date, time, patient ID, lab ID, operator ID, site ID, control ID

POCT1-A over Ethernet connection

Analyzer: 4-50°C (39-122°F)
Microcuvettes: 15-35°C (59-95°F)

For individually packaged microcuvettes: once the wrapping of a single packaged microcuvette is opened, it should be used within 10 minutes.

For microcuvette packaged in vial: once the seal of the vial is broken, the microcuvette should be used within 3 months.

Venous/capillary samples in EDTA: 18-30°C (64-77°F)

Capillary sample from fingerstick: 18-25°C (64-77°F), <90% non-condensing humidity

188 x 157 x 155 mm
(7.40 x 6.18 x 6.10 inches)

1300 g (2.87 pounds) with batteries installed

Lab-quality results in
three simple steps

Step 1 - How to use the HemoCue® WBC DIFF System
01

Fill the microcuvette

Step 2 - How to use the HemoCue® WBC DIFF System
02

Place the microcuvette into the analyzer

Step 3 - How to use the HemoCue® WBC DIFF System
03

View results within 5 minutes


Frequently Asked
Questions


There are two different controls available: HemoCue® WBC Control and HC WBC Diff Control, which should be used with the HemoCue® WBC System and HemoCue® WBC DIFF System, respectively. These controls are manufactured by R&D Systems, Inc and distributed outside the US by EuroCell Diagnostics.

No, only the HC WBC Diff Control should be used with HemoCue® WBC DIFF System.

The HemoCue® WBC DIFF System can be used with either HemoCue® WBC Microcuvettes (for a total white blood cell count) and HemoCue® WBC DIFF Microcuvettes (for a total white blood cell count with a 5-part differential).

Yes, the HemoCue® WBC DIFF System can be operated with either a power adapter or 6 type C 1.5 V Alkaline batteries. When battery operated, actual performance will vary based on settings, environmental conditions, type of batteries and other factors. Estimated number of measurements using batteries is 20 measurements.

A white blood cell count result should always be interpreted in the context of patient history and other clinical signs. The HemoCue® WBC DIFF system will display a flag or an error code if a problem is detected within the system or samples. The explanations and recommended actions for each flag or error code are described in the manual.

You can find instructional videos for all systems at our Knowledge Center.

Can’t find the answer you’re looking for? Fill in the form and we’ll reach out.