HemoCue® Hb 201 DM System

HemoCue®
Hb 201 DM-system

Enhance your patient safety and simplify your workflow. The HemoCue® Hb 201 DM System offers the lab accuracy and ease of use that has become a standard in Hb point-of-care testing, while also providing improved patient safety with features like QC lockout and built-in barcode scanning of patient ID.

HemoCue® Hb 201 DM System

Produktblad

Download

Key benefits

Improve your administrative workflow and safeguard patient testing and data with our data management solution in hemoglobin point-of-care testing. The HemoCue® Hb 201 DM System offers a complete data management solution for Hb testing and anemia screening through bi-directional communication and flexible settings.

01

Resultater inden for 1 minut

02

Indbygget selvtest til kvalitetskontrol

03

Knyt patientoplysninger og kommentarer til testresultater

04

Reducer fejl med automatisk overførsel af resultater

05

Problemfri integration med eksisterende netværk via POCT1-A

06

Nem at anvende efter kort oplæring


Kundehistorier

Sorry, no results were found.

Systemspecifikationer

Modified azidemethemoglobin reaction; dual wavelengths (570 nm and 880 nm) for compensation of turbidity

Calibrated against the hemiglobincyanide (HiCN) method, the international reference method recommended by the ICSH, for the determination of the hemoglobin concentration in blood. The system is factory calibrated and needs no further calibration

Internal rechargeable batteries or powered with AC adapter direct or in docking station

Built-in self-test, optional liquid controls

Capillary, venous or arterial whole blood

~10 µL

0.5-25.6 g/dl (5-256 g/L, 0.3-15.9 mmol/L)

15-60 seconds

Analyzer: 170 x 93 x 50 mm (6.70 x 3.66 x 1.97 inches)
Docking station: 135 x 206 x 61 mm (5.30 x 8.10 x 2.40 inches)

Analyzer: 350 g (0.77 lbs) with batteries installed
Docking station: 566 g (1.24 pounds)

Analyzer: 0-50°C (32-122°F)
Microcuvettes: unopened 15-30°C (59-86°F); three-month open vial stability

18-30°C (64-86°F)

Data management features

Touchscreen display, built-in barcode scanner*

Interface with existing software solutions using POCT1-A (CLSI standard). Docking solution enables connection of up to 5 analyzers

Operator ID, Patient ID, Lot ID, patient test comments, critical value alerts, STAT testing

4.000 patient/STAT tests, 500 QC tests, 500 analyzer logs, 200 patient IDs

QC lock-out

Linearity and proficiency testing

*LASER LIGHT
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT

Laser Warning

Lab-quality results in
four simple steps

Step 1 - How to use the HemoCue® Glu 201 DM System
01

Fill the microcuvette

Step 2 - How to use the HemoCue® Hb 201 DM System
02

Place the microcuvette into the analyzer

Step 3 - How to use the HemoCue® Hb 201 DM System
03

View results in under 1 minute

Step 4 - How to use the HemoCue® Hb 201 DM System
04

Seamlessly interface with your network


Frequently Asked
Questions

If the function on the display is not responding when pressed, the display may need to be recalibrated. Please read the Operating Manual for a detailed explanation of the procedure.

Once configured, the HemoCue® PDS+ Docking Station can be connected to the network with a LAN cable. HemoCue® SDS+ Docking Stations (up to 4) can be connected to a HemoCue® PDS+ Docking Station allowing docking of multiple analyzers for charging and transfer of data.

To receive a digital version of the Instructions for Use for your system, fill in the form and we’ll reach out.

You can find instructional videos for all systems at our Knowledge Center.

Please visit the HemoCue Web Academy to enroll in product trainings.

Kan du ikke finde det svar, du leder efter? Udfyld formularen, så kontakter vi dig.